Landowners
Self-builders and owners who want Passive House-level Comfort and predictable performance.
Progettazione e costruzione Passive House
We connect architettura, envelope decisions, airtightness, ventilation and coordinamento in cantiere so energy performance is designed into the progetto rather than patched later.

Che cos’è questo servizio
We design and deliver passive-level Homes by coordinating insulation, airtightness, thermal bridges, HRV, high-performance windows, BIM, permits, tender supporto and site QA.
Self-builders and owners who want Passive House-level Comfort and predictable performance.
Projects where low operating cost and marketability matter.
Owners who need architect-led coordinamento through design, tender and costruzione.
Projects that need a route from PHPP decisions to site QA and Consegna del progetto.
Cosa ricevi
U-values, insulation strategy, glazing ratio, orientation and shading.
Air barrier logic, junction details and blower-door test pianificazione.
Junction psi-value reduction and detail strategy.
Balanced supply/extract, filtration, acoustics and maintenance access.
Targets, variants and result summaries for decisions.
Permit drawings, schedules, tender supporto and costruzione checks.
Processo e tempi
A typical one-off Home moves through Concept, BIM and permits, tender, contracting and costruzione. Authority timing, size and system choice affect the programme.
Comfort, energy, budget, preferred systems and climate assumptions.
Massing, glazing, shading and early performance testing.
Coordinated plans, sections, details, schedules and specifications.
Pricing supporto, BOQ/VE supporto and impresa clarifications.
Site checks, airtightness tests, commissioning and Consegna del progetto records.
Tariffe
The parent page includes design scope ranges, realizzazione Tariffe and quick examples. They are rebuilt here as cards plus a real table.
Ideale per: Architect + PHPP + coordinamento through permit and tender.
Typical total design-only range, lower as a percentage on larger or simpler Homes.
Ideale per: Projects where Danica coordinates general impresa / CM realizzazione.
Pre-costruzione, gestione, close-out and costruzione realizzazione control.
Ideale per: Performance verification and optional third-party certification.
Specialist performance checks are usually priced separately from design scope.
| Home size | Assumed build cost | design (9-12%) | GC/CM 10% | Tests & cert. est. |
|---|---|---|---|---|
| 120 m2 | EUR 1,600/m2 -> EUR 192,000 | EUR 17,000-23,000 | EUR 19,200 | EUR 3,000-6,000 |
| 180 m2 | EUR 1,700/m2 -> EUR 306,000 | EUR 27,000-37,000 | EUR 30,600 | EUR 3,000-6,000 |
| 250 m2 | EUR 1,800/m2 -> EUR 450,000 | EUR 36,000-50,000 | EUR 45,000 | EUR 3,000-6,000 |
Perché è importante
Comfort, low running cost and airtightness are won through early decisions, consistent details and disciplined QA rather than a single expensive material choice.
Plot survey/topo, constraints, target area, preferred systems, budget envelope and timeline.
PHPP model, BIM drawings, airtightness details, junction catalogue, tender package and QA checklists.
Blower-door testing, HRV balancing, commissioning and as-built documentation.
Passive performance is not one visual style; we keep the physics right under the chosen architettura.

pianificazione a low-energy Home?
We will confirm the right scope: PHPP pre-check, Concept, permit package, tender supporto or design-build coordinamento.